Updated November 23, 2026 · Indumor
The least count of a vernier is the smallest beam division divided by the number of vernier divisions. A millimeter beam with a 20-division vernier resolves 0.05 mm. The same goes for inches and degrees.
Rule of ten: the least count of the instrument should be at most one tenth of the tolerance you are going to check.
The vernier has divisions slightly smaller than the ones on the beam. That is why only one of its lines ever lines up with a beam line, and which one it is tells you how many fractions of a division to add.
a: least count · d: smallest division of the beam (1 mm, 1/16 in, 1°) · n: number of vernier divisions · k: number of the vernier line that coincides.
Worked example · the 0.05 mm caliper
It is the one loaded above: a millimeter beam and a 20-division vernier.
Inch calipers come with two. The fractional one, 8 divisions over 7/16 in, resolves 1/128 in; the decimal one, 25 divisions against a beam graduated in 0.025 in, resolves one thou. The universal bevel protractor reads like a caliper, with 12 divisions against a beam in degrees. And a micrometer thimble follows the same sum: a 0.5 mm pitch over 50 divisions, 0.01 mm.
Vernier types (ISO 13385-1, DIN 862)
| Vernier | Beam division | Divisions | Vernier length | Least count |
|---|---|---|---|---|
| Tenths of a millimeter | 1 mm | 10 | 9 mm | 0.1 mm |
| 0.05, short | 1 mm | 20 | 19 mm | 0.05 mm |
| 0.05, long | 1 mm | 20 | 39 mm | 0.05 mm |
| 0.02 | 1 mm | 50 | 49 mm | 0.02 mm |
| Fractional inch | 1/16″ | 8 | 7/16″ | 1/128″ (0.198 mm) |
| Decimal inch | 0.025″ | 25 | 0.6″ | 0.001″ (0.0254 mm) |
| Decimal inch, long | 0.025″ | 25 | 1.225″ | 0.001″ (0.0254 mm) |
| Universal bevel protractor | 1° | 12 | 23° | 5′ |
The practical rule is the rule of ten: the least count should be at most one tenth of the tolerance. A shaft with 0.2 mm of tolerance is measured with a 0.02 caliper, and a 0.05 caliper does not check a 0.05 tolerance. How many microns each fit has is in the ISO fit calculator.
Divide the smallest beam division by the number of vernier divisions. With a millimeter beam and 20 divisions: 1 mm ÷ 20 = 0.05 mm.
Against a millimeter beam, two hundredths: 1 mm ÷ 50 = 0.02 mm.
Note the last whole millimeter the vernier zero has passed and find the only vernier line that coincides with a beam line. If the zero is past 23 and line 13 coincides: 23 + 13 × 0.05 = 23.65 mm.
The full table and the explanation are in chapter 2 of the machinist's handbook: Reading a caliper and a micrometer.
Sources: ISO 13385-1 (calipers); DIN 862; ASME B89.1.14 (calipers). Least count is a = d / n and the reading is beam + k · a.
Hole and shaft limits, plus the clearance or interference of an ISO 286 fit from 1 to 500 mm.
Open the calculator →How much a part grows with temperature and what a hot measurement will read at 20 °C.
Open the calculator →Twenty-five chapters of shop tables, drawings and worked examples.
See the contents →Laser cutting, bending, machining and welding under one roof.
© Indumor 2010–2026 — Industrial steel fabrication, Córdoba, Argentina